IEA858E ACR COMPLETE CPU NOW OFFLINE [PHYSICAL VARY FAILED]
Explanation
A failing processor was placed logically offline
by alternate CPU recovery (ACR). In the message text:
- PHYSICAL VARY FAILED
- The service processor tried unsuccessfully to vary the failing processor physically offline or the physical vary function is not supported by the service processor.
System action
The system continues processing. The system writes a logrec data set error record.
The system does not automatically remove this message from the display console. The operator must manually delete the message.
Operator response
Delete the message from the console with the CONTROL(K) command.
If this ACR was initiated by an earlier response to the excessive spin-loop message IEE331A, enter the CONFIG command to configure CPU x back online.
If PHYSICAL VARY FAILED appears in the message text, take processor x physically offline with the CONFIG CPU, OFFLINE command.
Contact hardware support. Provide the logrec data set error record.
Source
Alternate CPU recovery (ACR)
Module
IEAVTACR
Routing code
2,10
Descriptor code
4