IEA849I SYSMDUMP DATA SET FULL NO DUMP TAKEN TO dsname
Explanation
The system attempted to write a SYSMDUMP ABEND dump to a SYS1.SYSMDPxx data set with a disposition of SHARE. There was no end-of-file (EOF) indicator in the first record of the data set. The absence of an EOF indicator signals that the data set is full; therefore, the system could not write the SYSMDUMP. The dump is lost.
In the message text:
- dsname
- The data set to which the dump was to be written.
System action
The system continues processing.
System programmer response
Create a routine that copies the SYSMDUMP from its data set to another data set and writes an EOF indicator as the first record. Because the system issues message IEA993I each time it writes a SYSMDUMP, include the routine in the installation exit routine for the WTO macro that issues IEA993I.
Source
Recovery termination manager (RTM)
Module
IEAVTABD
Routing code
1
Descriptor code
-