IEA829I   SVC num FOR aaa NOT USABLE, MODULE bbb NOT FOUND IN ccc.

Explanation

The system needed a module for a program product or access method Supervisor Call (SVC) request, but the system could not find the module in either the nucleus (NUC) or link pack area (LPA).

In the message text:
num
The program product or access method SVC number
aaa
The program product or access method that appeared to be installed
bbb
The module needed for the specified SVC request that was not found
ccc
One of the following:
  • LPA for the link pack area
  • NUC for the nucleus

System action

The system does not update the SVC table entry for this SVC. The system will abnormally end any program trying to use this SVC.

System programmer response

Check to see if the specified product is installed, or should be.
  • If it is installed, check that it is installed correctly.
  • If it is not installed but should be, install it.

Source

Supervisor control

Module

IEAVNPST

Routing code

2,10

Descriptor code

4