IEA599I CLOCKxx LINE nnnn: text STMT IGNORED. UNRECOGNIZED PARM.
Explanation
A statement in a CLOCKxx parmlib member contains an incorrect parameter or statement type.
In the message text:
- CLOCKxx
- The parmlib member, with the suffix xx.
- nnnn
- The line number in the CLOCKxx parmlib member
that contains the ignored statement.
- If the statement type is not recognized, nnn is the line number of the previous valid statement.
- text
- The statement that contains the incorrect parameter.
- If the statement type is not recognized, text is the previous valid statement type.
System action
The system ignores all CLOCKxx parmlib members. The system issues message IEA906A.
Operator response
Reply to message IEA906A. If you press the
enter button on the console, the system sets the following defaults:
- The system does not prompt the operator during time-of-day (TOD) initialization.
- The system sets the local time equal to the Greenwich mean time (GMT).
System programmer response
Check for misspelled parameters in the CLOCKxx parmlib member from the specified keyword to the end.
Source
Timer supervision
Module
IEAVNP20
Routing code
2
Descriptor code
12