IEA502A   RESTART REASON COULD NOT BE OBTAINED. REPLY WITH RESTART REASON CODE:

Explanation

  • 0 - ABEND CURRENT PROGRAM
  • 1 - PERFORM MVS™ SYSTEM DIAGNOSTICS

[PREVIOUS REPLY WAS INVALID, ENTER A VALID REPLY]

Following a restart interruption, the system could not obtain the restart reason code from the service processor.

System action

The system issues message IEA501I. The system waits for the operator to reply.

Operator response

Reply one of the following:
0
The system responds with message IEA500A, which allows you to abnormally end the current program.
1
The system checks and repairs critical data areas.

When this message is issued, IT IS EXTREMELY IMPORTANT to respond promptly. This message is issued as a synchronous WTOR, which will prevent the system from updating its status on the sysplex couple data set. This, in turn, could lead to Sysplex Failure Management (SFM) deciding that the system is not responding normally, and removing it from the sysplex.

Source

Loadwait/Restart

Module

IEAVEREX

Routing code

Note 12

Descriptor code

-