IEA500A RESTART INTERRUPT DURING {jobname stepname|UNKNOWN JOBNAME} ASID=aaaa MODE=mmmm PSW=psw REPLY RESUME TO RESUME INTERRUPTED PROGRAM REPLY ABEND TO ABEND INTERRUPTED PROGRAM [PREVIOUS REPLY WAS INVALID, ENTER A VALID REPLY]
Explanation
When the operator caused a restart interruption, the specified job was in progress. The message asks the operator to resume the job that was in progress or end it.
In the message
text:
- jobname
- The name of the job that the system was currently processing.
- stepname
- The name of the step that the system was currently processing or blanks.
- UNKNOWN JOBNAME
- The system could not identify the current job.
- ASID=aaaa
- The address space identifier (ASID)
- MODE=mmmm
- The system was processing one of the following units of work:
- TASK
- A task
- SRB
- A service request
- WAIT
- The system wait task
- *
- A unit of work other than those listed above
- PSW=psw
- The 16-byte program status word (PSW) at the time of the restart interruption.
System action
The system prompts the operator for a reply.
Operator response
Reply one of the following:
- RESUME
- The job that was in progress continues at the next sequential instruction.
- ABEND
- The system ends the job with abend X'071'.
When this message is issued, IT IS EXTREMELY IMPORTANT to respond promptly. This message is issued as a synchronous WTOR, which will prevent the system from updating its status on the sysplex couple data set. This, in turn, could lead to Sysplex Failure Management (SFM) deciding that the system is not responding normally, and removing it from the sysplex.
Source
Loadwait/Restart
Module
IEAVEREX
Routing code
Note 12
Descriptor code
-