IEA481I CONTROLLER NOT OPERATIONAL WITH STORAGE PATH - device-number/ssid.p-cc-nn SENSE=sense
Explanation
The specified DASD controller cannot be accessed
through the specified storage path. In the message text:
- device-number
- The physical device address.
- ssid
- The subsystem identifier.
- p
- The storage path.
- cc
- The controller address.
- nn
- The device number.
- sense
- The 32 characters of sense data reported by the device.
xxxx xxxx xxxx xxxx xxxx xxxx xxxx xxxx
System action
Processing continues.
Operator response
The system issues this message because of a hardware error. Follow your installation's procedures for reporting this error. If the device associated with this message is attached by way of the IBM® 3990 Model 3 or Model 6 Storage Control, contact IBM hardware support for detailed recovery actions.
Source
DFSMSdfp
Module
IGGSNS01
Routing code
1,6
Descriptor code
4