IEA354I [CLPA|MLPA|BLDL|IOSDLPAL] FAILED - text
Explanation
The system link pack area (LPA) or the pageable
build directory entry list (BLDL) table could not be created. text indicates
the reason:
- LPALIB UNAVAILABLE
- The SYS1.LPALIB data set is not defined in the catalog or the data set could not be opened. The reason for the failure is given in the previous message.
- LPALIB EMPTY
- The SYS1.LPALIB data set did not contain any load modules.
- STORAGE UNAVAILABLE
- Virtual storage is too small to contain all the modules in SYS1.LPALIB. The number of modules in SYS1.LPALIB must be reduced if cold start is to be successful.
- I/O ERROR
- An I/O error occurred when the nucleus initialization program (NIP) attempted to read a record from the SYS1.LPALIB directory.
- PGOUT ERROR
- An error occurred during the processing of the PGSER macro. The PGSER macro tried to page out the modified link pack area (MLPA) area, pageable link pack area (PLPA) area, or the pageable BLDL list.
- NON-EXECUTABLE MODS
- Non-processible modules were found on SYS1.LPALIB.
System action
The system enters non-restartable wait state X'03A'. If any modules were successfully loaded into the LPA, the system issues message IEA353I.
Operator response
This is probably an installation error. Notify the system programmer.
System programmer response
If the error recurs and the program is not in error, search problem reporting data bases for a fix for the problem. If no fix exists, contact the IBM® Support Center.
Source
Contents supervision (CSV)
Module
IEAVNP05, IEAVNPC5
Routing code
-
Descriptor code
12