IEA343D   NUCLEUS OVERLAPS PLPA, RE-IPL OR REPLY ‘GO’ FOR COLD START

Explanation

The nucleus overlaps into the previous system queue area/extended system queue area (SQA/ESQA) area. This causes an overlap into the area required by pageable link pack area (PLPA) or extended PLPA (EPLPA). This might have been caused by one of the following:
  • The size of the nucleus increased.
  • The amount of central storage increased; this increase results in an increase in the size of the nucleus.
PLPA and EPLPA must be in the same virtual storage location as the previous IPL for warm starts to proceed. Therefore, the quick or warm start cannot proceed. The operator must reIPL or allow the IPL to change to a cold start.

System action

This message requests a response from the operator. If the operator replies GO, the system issues message IEA929I (CLPA FORCED), changes the IPL to a cold start, and continues paging initialization. Otherwise, the operator must reIPL.

Operator response

Determine if the correct nucleus was specified at IPL. If not, specify the correct nucleus and reIPL. If the correct nucleus was specified at IPL, notify the system programmer.

System programmer response

If the problem cannot be resolved, search problem reporting data bases for a fix for the problem. If no fix exists, contact the IBM® Support Center.

Source

Auxiliary storage manager (ASM)

Module

ILRASRIM

Routing code

Note 9

Descriptor code

2