IEA340I REAL OR VIRTUAL STORAGE NOT AVAILABLE FOR func
Explanation
The nucleus initialization program (NIP) could not obtain storage for the function indicated.
- func
- The function is one of the following:
- BLDL/BLDLF
- FIX
- IOSDLPAL
- LPA Device Support Modules
- MLPA
- PFT
System action
If func is not a necessary system function, the system will continue processing. If, however, func is a necessary system function, the system enters disabled wait state X'038' or X'03A'.
- func
- System Action
- PFT
- Wait state X'038'
- LPA Device
- Wait state X'03A'
- Support
- Modules
- BLDL/BLDLF
- Respecification offered by prompt message
- MLPA
- The system issues message IEA353I
- FIX
- The system issues message IEA353I
Operator response
Report this message to the system programmer.
System programmer response
If the error recurs and the program is not in error, search problem reporting data bases for a fix for the problem. If no fix exists, contact the IBM® Support Center.
Programmer response
If message IEA956I or message IEA968I was issued previously, probable hardware error. Central storage might have a defective frame located at a fairly low address If message IEA956I or message IEA968I was not issued previously, this is probably an installation error. Make sure that sufficient storage is available for NIP processing. Reduce the number or the size of your optional system facilities, such as the fixed link pack area (FLPA) or the fixed BLDL list.
Source
Contents supervision (CSV)
Module
IEAVNP05
Routing code
Note 9
Descriptor code
12