IEA340I   REAL OR VIRTUAL STORAGE NOT AVAILABLE FOR func

Explanation

The nucleus initialization program (NIP) could not obtain storage for the function indicated.

In the message text:
func
The function is one of the following:
  • BLDL/BLDLF
  • FIX
  • IOSDLPAL
  • LPA Device Support Modules
  • MLPA
  • PFT

System action

If func is not a necessary system function, the system will continue processing. If, however, func is a necessary system function, the system enters disabled wait state X'038' or X'03A'.

Functions and system actions are as follows:
func
System Action
PFT
Wait state X'038'
LPA Device
Wait state X'03A'
Support
Modules
BLDL/BLDLF
Respecification offered by prompt message
MLPA
The system issues message IEA353I
FIX
The system issues message IEA353I
Note: PFT is not a system parameter.

Operator response

Report this message to the system programmer.

System programmer response

If the error recurs and the program is not in error, search problem reporting data bases for a fix for the problem. If no fix exists, contact the IBM® Support Center.

Programmer response

If message IEA956I or message IEA968I was issued previously, probable hardware error. Central storage might have a defective frame located at a fairly low address If message IEA956I or message IEA968I was not issued previously, this is probably an installation error. Make sure that sufficient storage is available for NIP processing. Reduce the number or the size of your optional system facilities, such as the fixed link pack area (FLPA) or the fixed BLDL list.

Source

Contents supervision (CSV)

Module

IEAVNP05

Routing code

Note 9

Descriptor code

12