IEA323I   OPI INVALID IN mem

Explanation

The nucleus initialization program (NIP) found an incorrect OPI parameter in a IEASYSxx parmlib member. The OPI parameter must be specified as either OPI=YES or OPI=NO.

In the message text:
mem
The IEASYSxx parmlib member containing an incorrect OPI parameter

System action

The system ends the input from the member and issues message IEA324I. The system issues message IEA336A to prompt the operator to respecify the SYSP parameter.

Operator response

Respond to message IEA336A by specifying the SYSP parameter again or cancelling the use of it for this IPL. Parameters interpreted up to the point of the error remain in effect.

System programmer response

Make sure that the IEASYSxx parmlib member correctly specifies the SYSP parameter. Ensure that the SYSP list of system parameters is specified correctly.

Source

System initialization (IPL/NIP)

Module

IEAVNP03