IEA323I OPI INVALID IN mem
Explanation
The nucleus initialization program (NIP) found an incorrect OPI parameter in a IEASYSxx parmlib member. The OPI parameter must be specified as either OPI=YES or OPI=NO.
In
the message text:
- mem
- The IEASYSxx parmlib member containing an incorrect OPI parameter
System action
The system ends the input from the member and issues message IEA324I. The system issues message IEA336A to prompt the operator to respecify the SYSP parameter.
Operator response
Respond to message IEA336A by specifying the SYSP parameter again or cancelling the use of it for this IPL. Parameters interpreted up to the point of the error remain in effect.
System programmer response
Make sure that the IEASYSxx parmlib member correctly specifies the SYSP parameter. Ensure that the SYSP list of system parameters is specified correctly.
Source
System initialization (IPL/NIP)
Module
IEAVNP03