IEA266I   CLOCKxx: {ETRMODE NO AND ETRZONE YES|OPERATOR PROMPT AND SIMETRID} ARE MUTUALLY EXCLUSIVE PARMS.

Explanation

Both ETRMODE NO and ETRZONE YES, or OPERATOR PROMPT and SIMETRID, were specified in a CLOCKxx parmlib member. The timer synchronization mode must be External Time Reference (ETR) (ETRMODE YES) to obtain the time zone value from the ETR. ETR is the MVS™ generic name for the IBM® Sysplex Timer (9037) or equivalent.

In the message text:
CLOCKxx
The parmlib member, with the suffix xx.

System action

The system ignores all CLOCKxx parmlib members. The system issues message IEA906A.

Operator response

Reply to message IEA906A. If you press the enter button in reply to message IEA906A, the system sets the following default values:
  • No operator prompting for time-of-day (TOD) initialization.
  • ETR synchronization mode.
  • ETRDELTA value of 10 seconds.
  • Time zone constant obtained from ETR (or set to 0 if time zone cannot be obtained from ETR).

System programmer response

Specify the correct synchronization mode (ETRMODE) in the CLOCKxx parmlib member.

If you specify ETRMODE NO, you cannot specify ETRZONE YES.

Source

Timer supervision

Module

IEAVNP20

Routing code

2

Descriptor code

12