IEA084W ENTRY POINT entrypt NOT FOUND IN THE NUCLEUS
Explanation
During system initialization, the system could
not find an entry point in the nucleus for one of the following:
- A device descriptor table (DDT)
- An error recovery program (ERP)
- The unit control blocks (UCB)
- The device class queue (DCQ)
- The device characteristic table (DCT)
- An incomplete nucleus
- An incomplete I/O configuration
- Both an incomplete nucleus and an incomplete I/O configuration
In the message text:
- entrypt
- The entry point address.
System action
The system enters nonrestartable disabled wait state X'035'.
Operator response
See the operator response for wait state X'035'.
System programmer response
See the system programmer response for wait state X'035'.
Source
Input/output supervisor (IOS)
Module
IEAIPL03