IEA040W REMOTE SLIP TRAP ID=xxxx FROM SYSTEM ssssssss MATCHED. ACTION=WAIT RESTART THE SYSTEM TO CONTINUE
Explanation
A remote system found a match for a SLIP trap. The SLIP trap requested that this system be placed into a wait state so that the operator could capture diagnostic data.
In the message
text:
- ID=xxxx
- The SLIP trap identifier specified on the SLIP command.
- ssssssss
- The system on which the trap matched.
System action
This system is placed into a restartable wait state.
Operator response
Perform the actions requested by the system programmer for this trap.
Either:
- Restart the system.
- Obtain a stand-alone dump and reIPL the system.
System programmer response
To capture diagnostic data, ask the operator to obtain a stand-alone dump. The system cannot be restarted if a stand-alone dump is written; ask the operator to reIPL the system.
Source
SLIP
Module
IEAVTSL5
Routing code
1
Descriptor code
1