IDC31864I OFFSET PAIR number1 RANGE OVERLAPS OFFSET PAIR number2
Explanation
INSERTSHIFT was specified on an access method services (AMS) PRINT or REPRO copy of a data set operation. AMS, while checking offset values, detected that a set of offset pairs had overlapping ranges. This would cause the data to fail during DBCS criteria checking.
In
the message text:
- number1 and number2
- The offset pairs with overlapping values.
System action
The command is ended. The return code is 12.
Programmer response
Recheck the offset pair specifications in the INSERTSHIFT keyword. You should make sure that offset pair values do not overlap.
Source
DFSMSdfp