IDC11373I THE FOLLOWING COMPARE ELEMENTS WERE NOT ENCOUNTERED
Explanation
The names that follow this message were given in the comparison list but were not encountered during processing. The entries may no longer be in the catalog or VVDS.
System action
DIAGNOSE considers this an attention condition and continues processing the catalog or VVDS.
Programmer response
Check the spelling carefully. If you are
using DD statements to define catalogs, ensure that a DSNAME has been
coded. If a volume serial number has been coded, ensure that it is
correct. If the command is correctly coded, take the following steps:
- For a BCS, use LISTCAT to verify the catalog contains an entry for the listed VVDS. Determine whether any data sets in the catalog are missing volume entries. If volume entries are missing, use DEFINE RECATALOG to recatalog these data sets and to pick up missing volumes. If volume entries are not missing, change the DIAGNOSE command to remove the reference to the missing compare name; there is no error.
- For a VVDS, determine whether any VVDS entries should be referencing the named catalog.
If the entry is in the catalog but DIAGNOSE cannot locate it, contact your service representative.
Source
DFSMSdfp
Module
IDCDA03