IDC3582I   INPUT DATA SET ORGANIZATION INCOMPATIBLE WITH OUTPUT DATA SET

Explanation

When you attempt to copy information from one data set into another, this error condition occurs when one of the following is true:
  • the source is a non-relative record data set and the target is a non-empty relative record data set that is not specified for reuse; or
  • one data set is linear and the other data set is non-linear. The LRECL of the physical sequential data set is not equal to the CISIZE of the linear data set.

System action

The command is ended.

System programmer response

If the error recurs and the program is not in error, search problem reporting data bases for a fix for the problem. If no fix exists, contact the IBM® Support Center. Provide the JCL and the SYSOUT output for the job.

Programmer response

Check the status of the input and output data sets. REPRO is unable to satisfy your request. Set up data sets correctly and rerun the job.

Source

DFSMSdfp

Module

IDCRP01