IDC3030I   CONTROL INTERVAL SIZE TOO LARGE

Explanation

The data component control interval size specified is greater than 32,768 or the index component control interval size is greater than the maximum block size of the index device. See the associated second-level message for the specific catalog management error code values.

In the Time Sharing Option/Extensions (TSO/E) environment the second-level message is not displayed, except by request. To request it, enter a question mark (?) after the TSO READY message.

System action

The system ends the command.

Programmer response

Do one of the following:
  • Reduce the control interval size.
  • If the error occurred due to the index component's device type, use a different device with a larger blocksize.

Source

DFSMSdfp

Module