IDC2886I UNABLE TO REFERENCE CRA ON VOLUME ser - REASON CODE cde
Explanation
When opening the catalog recovery area (CRA) the system detected an error.
In the message text:
- ser
- The volume serial number.
- cde
- The hex reason code, as follows:
- Codes
- Explanation
- 1
- Cannot verify the CRA.
- 2
- Cannot open the CRA.
- 4
- I/O error on control interval No.0
- 5
- I/O error on control interval No.3
- 7
- Error on number of directories.
- 8
- Error on directory entries.
System action
The system marks the CRA as bad. No entries are placed on the portable data set.
Programmer response
If the reason code is 1, 2, 4, or 5, restore the volume on which the error occurred to a previous valid condition.
If the reason code is 7 or 8, provide the FORCE keyword in the EXPORTRA command to override the synchronization problem.
Source
DFSMSdfp
Module
IDCRC01