ICU1030   INVALID SMF DATA LENGTH FROM INSTALLATION EXIT; PROCESSING TERMINATES

Explanation

The key generator installation exit routine returned the SMF buffer with a value greater than 64 in the length field.

System action

The key generator utility program does not include the installation-defined data in the SMF record. The program writes the SMF record to the SMF data set and stops processing.

Programmer response

Check the installation exit routine to determine if there are any problems in the module and make any necessary corrections. Link edit the key generator utility program with the corrected exit routine. See z/OS DFSMS Using Data Sets Rerun the key generator utility program as follows. If the SETM or CHGM function was requested and the host master key was not set (message ICU010I was not issued), rerun the entire job. Otherwise, use this listing to determine which control statements were processed successfully. Then rerun the utility program using the CHGK function to process the remaining control statements. Notify the security administrator.

To ensure that you have all the messages issued for this problem, specify MSGLEVEL=(1,1) for the job.

Source

Cryptographic Unit Support Program (CUSP)