ICT1025   REQUIRED INPUTS FOR KEY GENERATION NOT AVAILABLE

Explanation

The key generator utility program attempted to generate a key for a control statement and either a problem occurred with the time-of-day (TOD) clock or a valid seed value was not supplied on the EXEC statement. Message ICT1018, which identifies the specific problem, and the control statement being processed when the problem occurred, precede this message.

System action

Processing ends for this control statement. Processing continues for any other control statements.

Programmer response

Respond as follows:
  • If message ICT1018 stated that there is a problem involving the TOD clock, contact your service representative.
  • If message ICT1018 stated that a seed value was supplied, add a seed value to the EXEC statement.

Rerun the key generator utility program specifying the CHGK function on the EXEC statement and providing the control statement that was being processed when the problem occurred.

Source

Programmed Cryptographic Facility (PCF)

Module

ICTMKG01