ICT1024 REQUIRED OPERAND[S] MISSING; STATEMENT IGNORED
Explanation
While scanning a SYSIN control statement, the key generator utility program could not find one or more required parameters. LOCAL, REMOTE, and CROSS control statements require a label. EXTRA-LOCAL, EXTRA-REMOTE, and EXTRA-CROSS control statements require a number and a label-base. The REASGN control statement requires an existing label and a new label. The control statement containing the error precedes this message.
System action
Processing ends for this control statement. Processing continues for any other control statements.
Programmer response
Correct the control statement. Rerun the key generator utility program, specifying the CHGK function on the EXEC statement and providing the corrected control statement.
Source
Programmed Cryptographic Facility (PCF)
Module
ICTMKG01