ICT033I   LOAD FAILED FOR CRYPTOGRAPHY INSTALLATION OPTIONS MODULE

Explanation

The Programmed Cryptographic Facility initialization process invoked by the operator START command or the key generator utility program was unable to load the installation options module, ICTOPTNS.

System action

Programmed Cryptographic Facility initialization processing ends.

Programmer response

Check the output of the install process (SMP) to verify that the installation options module was properly installed in SYS1.LINKLIB. Correct the problem and reissue the operator START command or rerun the key generator utility program.

To ensure that you have all the messages issued for this problem, specify MSGLEVEL=(1,1) for the job.

Source

Programmed Cryptographic Facility (PCF)

Routing code

*,10,11

Descriptor code

4