ICT030I CRYPTOGRAPHY INITIALIZATION UNABLE TO LOCATE name in LPA
Explanation
The Programmed Cryptographic Facility installation process invoked by the operator START command or the key generator utility program was unable to locate the routine specified by name in a search of the active link pack area queue and the link pack area directory.
System action
Programmed Cryptographic Facility initialization processing ends.
Operator response
Notify the system programmer.
Programmer response
Determine if the GENKEY or RETKEY installation exit routine (module ICTMGR90 or ICTMGR95) is properly link edited into SYS1.LPALIB. If the module has been replaced since the Programmed Cryptographic Facility was installed, check the linkage editor output from the most recent change. If it has not been replaced, check the output of the install process (SMP or SYSGEN) to see that the module was properly installed. Correct the problem and reissue the operator START command or rerun the key generator utility program.
To ensure that you have all the messages issued for this problem, specify MSGLEVEL=(1,1) for the job.
Source
Programmed Cryptographic Facility (PCF)
Routing code
*,10,11
Descriptor code
4