ICP056I   IOCP JOB jobname FAILED. DID NOT BUILD LEVEL xx IOCDS.

Explanation

A job was processing the input/output configuration program (IOCP) with a WRTCDS option other than NO on the PARM parameter of an EXEC statement.

In the message text:
jobname
The jobname.
xx
The specified level.

System action

IOCP ends the job with return code 8. IOCP issues this message to inform the programmer and the system operator, if the operator previously responded to message ICP050D, that this job failed to build the level indicated input/output configuration data set (IOCDS).

One of the following occurred:
  • An error was found in the IOCP input statements
  • The system operator previously replied 'NO' to message ICP050D
  • The CBD.CPC.IOCDS resource of the FACILITY class has been defined to an installed security product and you have not been authorized by the security administrator to update access to the CBD.CPC.IOCDS resource.

Operator response

Notify the system programmer that the job failed.

System programmer response

Review the messages on the job listing, and take the necessary actions.

Source

Input/output configuration program (IOCP)

Routing code

2,11,Note 32

Descriptor code

6