IEA383I   THIS SERVER RECEIVES TIMING SIGNALS FROM ONLY ONE OTHER NETWORK NODE.

Explanation

This server has timing links to only one other server. If the other server fails, this server will have no source of timing and will lose its timing also.

System action

The system continues processing.

Operator response

Notify the System Programmer.

System programmer response

Start of changeProvide an additional link or links to another server in the CTN to avoid a single point of failure. To avoid IEA383I being issued for a two-server CTN, the "Only allow the server(s) specified above to be in the CTN" button must be selected via the Network Configuration panel on the HMC.End of change

User response

N/A

Problem determination

N/A

Source

Timer supervision

Module

IEAVNP21, IEATEEIH

Routing code

10

Descriptor code

12

Automation

None.