IEAVEH050E   There are n remaining available LxTypes. This is below the limit

Explanation

The current number of available LxTypes is not greater than the checkowner_or_installation specified limit of specified.

System action

The system continues processing. However, if more LXs of the identified type are needed, a re-IPL may be necessary.

Operator response

Report this problem to the system programmer.

System programmer response

Run the check with the VERBOSE option. Look at the report output to see what LXs are in use. It may be possible to cancel one of the jobs that is identified and thereby allow the non-system LXs used by that job to be re-used.

Check the maximum number of system LXs specified in your IPL parameters by the NSYSLX parameter.

Problem determination

N/A

Source

Supervisor Control

Module

IEAVEHCK,IEAVEHMS

Routing code

See note 35.

Descriptor code

12 is the default set by this check. See note 1.

Automation

N/A