IEA075I   PPRC SUMMARY,SSID=xxxx,DEVICE NED=tttt.mmm.ggg.pp.ssssssssssss.uuuu,SECSSID=yyyy(Dddd Pppp Ssss),SECSSID=zzzz(Dddd Pppp Ssss),SECSSID=yyyy(Dddd Pppp Ssss),SECSSID=zzzz(Dddd Pppp Ssss),SUSPENDED=aaa,PPRC=bbb,TOTAL=ccc,{REASON=SUSPEND(rr),text | REASON=UNKNOWN(rr)}

Explanation

This message displays summarizes the PPRC state for all the devices in a control unit.

In the message text:
SSID=xxxx
SSID for this subsystem.
DEVICE NED=tttt.mmm.ggg.pp.ssssssssssss.uuuu
Node element descriptor from the device:
tttt
Machine type
mmm
Model
ggg
Manufacturer
pp
Plant of manufacture
ssssssssssss
Box sequence number
uuuu
Unique identifier for device with the same serial number. This value is the concatenation of device logical storage subsystem (LSS) and device CCA. The device CCA reported is one of potentially multiple devices with a PPRC state transition.
SECSSID=yyyy(Dddd Pppp Ssss),SECSSID=zzzz(Dddd Pppp Ssss)
Secondary SSID(s) associated with the PPRC secondary volume(s). Although there can be multiple secondary SSIDs associated with a primary SSID, only one secondary is shown for each relationship.
SECSSID=yyyy
SECSSID=zzzz
SSIDs for the devices in the secondary subsystems
ddd
Count of full duplex pairs for SSID relation xxxx:yyyy
ppp
Count of pending pairs for SSID relation xxxx:yyyy
sss
Count of suspended pairs for SSID relation xxxx:yyyy
SUSPENDED=aaa
The number of devices that are PPRC suspended devices in the LSS.
PPRC=bbb
The number of devices in a PPRC relationship in the LSS.
REASON=SUSPEND(rr)
Reason code for PPRC state transition. The accompanying text explains the reason code.
text
Displays the reason for the suspend, which is one of the following:Start of change
  • HOST COMMAND TO PRIMARY [rr = 03]
  • HOST COMMAND TO SECONDARY [rr = 04]
  • SECONDARY STATUS UPDATED[rr = 05]
  • CU INTERNAL CONDITIONS [rr = 06]
  • SECONDARY SIMPLEX [rr = 07]
  • SECONDARY INTERNAL CONDITIONS [rr = 08]
  • POWER® [rr = 09]
  • FREEZE [rr = 0A]
  • ESTABLISH FLASHCOPY [rr = 0C]
  • SECONDARY RELEASE SPACE [rr = 0E]
  • GLOBAL MIRROR PAUSE [rr = 0F]
End of change
REASON=UNKNOWN(rr)
Reason code not recognized.
TOTAL=ccc
The number of configured devices in the LSS.

System action

The system continues processing.

Operator response

This message is intended for use by automation programs that monitor operator messages. Actions can be attempted by the operator, but an automation program is recommended.

System programmer response

None.

Source

DASD device initialization/re-initialization

Module

IECCINIT

Routing code

Start of change

2, 6

End of change

Descriptor code

Start of change

4

End of change