IAZ0028I   server_name device_name Incorrect RCB, SRCB or length detected

Explanation

Incorrect data was found in a buffer which makes a record impossible to process. This could be caused by an invalid RCB, invalid SRCB, or inconsistent length.

In the message text:
server_name
The NJETCP server name.
device_name
The device name associated with the socket, or socket name if the device name does not exist.

System action

The X'EC8' abend is issued after the message and the corresponding socket connection is terminated. The system writes an abend dump.

Operator response

Restart the connection. If the problem persists, notify the system programmer.

System programmer response

Obtain the X'EC8' abend dump and other relevant documentation, and contact the IBM® Support Center.

Source

JES Common

Module

IAZNJSTK

Routing code

8, 43

Descriptor code

4