HWI052I   BCPII COMPONENT TRACE IS UNAVAILABLE DUE TO INTERNAL ERROR. BCPII PROCESSING CONTINUES. RC=rc, RSN=rsn.

Explanation

BCPii component trace initialization failed because of internal errors. BCPii component trace (SYSBCPII) is not available until the next time the BCPii address space is restarted.

In the message text:
rc
The return code from the CTRACE DEFINE macro.
rsn
The reason code from CTRACE DEFINE macro.

System action

BCPii operates without component tracing.

Operator response

Report this message to the system programmer.

System programmer response

Consider restarting the BCPii address space if CTRACE tracing is required. If problem occurs again after the restart, search problem reporting databases for a fix for the problem. If no fix exists, contact the IBM® Support Center.

User response

None.

Programmer response

None.

Module

HWIV1INT

Routing code

2

Descriptor code

4