HIS026I MODIFY hisproc COMMAND CANNOT BE PROCESSED.
failure-text
Explanation
- Not supported on this CPU
- Not installed on this CPU
- Are not authorized for use
- B (basic) and P or PROB (problem state) counter sets may be used if they are installed on the IBM® System z10™ or later machines. You must first get authorized to use these counter sets explicitly through the SE console.
- C (Crypto) and E (extended) counter set availability is model dependent and installation is optional. These counter sets also require explicit authorization through the SE console.
- The Z (z/OS®) counter set availability is model dependent and installation is optional. The counter set requires the Enhanced Monitor Facility be installed on the CPU.
- The MTD (MT-diagnostic) counter set is only available when the PROCVIEW CORE parameter is specified in the LOADxx parmlib member and running on hardware that supports multithreading (MT).
- The B (basic) sampling facility is installed and available on all the IBM System z10 or later machines. However, you must authorize the sampling facility through the SE console explicitly.
- The D (diagnostic) sampling facility availability is CPU model dependent and installation is optional. This sampling facility also requires explicit authorization through the SE console.
- hisproc
- The name of the HIS cataloged startup procedure.
- failure-text
- The failure-text explaining the problem is
one of the following ones:
- BASIC COUNTER SET IS UNAUTHORIZED
- The Basic counter set is unavailable.
System programmer action: Ensure that you authorize the indicated counter set for use by the hisproc HIS Catalogued startup procedure.
- PROBLEM-STATE COUNTER SET IS UNAUTHORIZED
- The Problem-state counter set is unavailable.
System programmer action: Ensure that you authorize the indicated counter set for use by the hisproc HIS Catalogued startup procedure.
- CRYPTO-ACTIVITY COUNTER SET IS UNAVAILABLE
- The Crypto-activity counter set is unavailable.
System programmer action: Ensure that the indicated optional counter set, if desired, is installed and authorized for use by the hisproc HIS Catalogued startup procedure.
- EXTENDED COUNTER SET IS UNAVAILABLE
- The Extended counter set is unavailable.
System programmer action: Ensure that the indicated optional counter set, if desired, is installed and authorized for use by the hisproc HIS Catalogued startup procedure.
- ZOS COUNTER SET IS UNAVAILABLE
- The z/OS counter set is
unavailable.
System programmer action: Ensure that the Enhanced Monitor Facility, if desired, is installed for use by the HIS catalogued startup procedure.
- BASIC SAMPLING FUNCTION IS UNAUTHORIZED
- The Basic sample function is unavailable.
System programmer action: Ensure that you authorize the basic sampling function for use by the hisproc HIS Catalogued startup procedure.
- DIAGNOSTIC SAMPLING FUNCTION IS UNAVAILABLE
- The Diagnostic sample function is unavailable.
System programmer action: Ensure that the indicated optional sampling function is installed and authorized for use by the hisproc HIS Catalogued startup procedure.
- MT-DIAGNOSTIC COUNTER SET IS UNAVAILABLE
- The MT-diagnostic counter set is unavailable.
System programmer action: Ensure that the hardware supports multithreading and requests multithreading exploitation via the PROCVIEW CORE parameter in the LOADxx parmlib member.
- NO COUNTER SETS ARE AVAILABLE
- No counters are installed or authorized.
System programmer action: Ensure that you authorize the indicated counter set for use by the hisproc HIS Catalogued startup procedure.
System action
The system does not process the command issued.
Operator response
Ensure that all the specified counter sets (CNTSET parameter) or sampling facility types (SAMPTYPE parameter) are installed and authorized on this system.
System programmer response
See the System programmer action in the explanation for the particular failure text displayed.
Problem determination
None.
Source
Hardware instrumentation services (HIS)
Module
HISICMD
Routing code
-
Descriptor code
5