HIS024I   NO ACTIVE ADDRESS SPACES MATCHED BY THE MAPJOB LIST. PRIVATE LOAD MODULE INFORMATION NOT MAPPED.

Explanation

During a data collection run initiated by the MODIFY hisproc command with parameter MAPJOB (but not MAPASID), the system found that it could not match any active address spaces from the list specified on the MAPJOB parameter. HIS will not produce any private load module information, but will produce mappings of the LPA and the nucleus.

The system issues this informational message only if it is unable to match any active address spaces from the information specified on the MAPJOB parameter (but not MAPASID) or if no MAPASID parameter has been specified.

Note: The jobs being mentioned identified in the data collection run must stay active for the mapping function to be performed. If the jobs end before the load module mapping is finished, (as indicated by system message HIS012I) the data collection run might not include private load module information for the ended jobs.

System action

The system continues processing.

Operator response

Issue the command again if necessary, specifying one or more active address spaces on the MAPJOB parameter. If private load module map information is not needed, you can let the current data collection continue proceeding.

System programmer response

None.

Problem determination

None.

Source

Hardware instrumentation services (HIS)

Module

Start of changeHISICMDEnd of change

Routing code

2

Descriptor code

4