IEA920I   PAGE DATA SET dsname NOT LOCATED

Explanation

The system could not use a page data set because either:
  • The system could not locate a data set in the master catalog.
  • The master catalog information does not agree with expected and necessary attributes of a page data set.
In the message text:
dsname
The name of the data set.

System action

The system continues initialization.

If the data set was newly specified during this IPL, the system issues message IEA922D to prompt the operator to respecify the data set name.

If PAGE is specified in the message text and the page data set is known from a previous IPL as containing VIO pages that should be used under current IPL options, the system issues message IEA930I. The system continues initialization.

In all other cases, the system issues message IEA922D.

Operator response

Reply to message IEA922D, if issued. Notify the system programmer.

System programmer response

Before the next system initialization, verify that the page data set is cataloged in the master catalog.

Source

Auxiliary storage manager (ASM)

Module

ILRASRM2

Routing code

Note 9

Descriptor code