IEA067I CROSS-MEMORY RESOURCE MONITORING HAS FAILED
Explanation
A fatal error occurred in the cross-memory monitoring task. Cross-memory resource monitoring will no longer occur until the system is re-IPLed.
System action
None.
Operator response
None.
System programmer response
None.
Source
Cross-memory services
Module
IEAVXSRM
Routing code
1,10
Descriptor code
None.