IEA059E ASID SHORTAGE HAS BEEN DETECTED
Explanation
The number of ASIDs available for allocation to new address spaces has dropped below 5% of the value specified in IEASYSxx with the MAXUSER specification.
System action
The first time MVS™ issues message IEA059E for the current IPL, MVS takes a system dump to aid in diagnosing the situation. System Completion code AC7 with reason code 001B0000 is issued to permit MVS to take the system dump.
Operator response
None.
System programmer response
Determine if the shortage is due to too many address spaces being started, MAXUSER being specified too low, or ASIDs becoming non-reusable for cross-memory integrity reasons.
Source
Cross-memory services
Module
IEAVXSRM
Routing code
1,10
Descriptor code
11