IEA886A TOD CLOCK(S) MUST BE SET
Explanation
The operator did not set the time-of-day (TOD) clock(s).
System action
The system prompts the operator for a reply. When you enter a valid reply to message IEA886A, the system issues message IEA903A.
Operator response
Use the following form of the REPLY command
to set the time of day clock.
R id,‘DATE=[yyyy.ddd[,CLOCK=hh.mm.ss][,GMT]’
In
the command text:
- id
- The reply identifier.
- yyyy
- The year (4 digit year: 1900 - 2042).
- ddd
- The day (001-366).
- hh
- The hour (00-23).
- mm
- The minute (00-59).
- ss
- The second (00-59).
Note: The apostrophes in the above reply are optional.
If you include GMT in your reply, the system converts the time and
date to Greenwich mean time. If you omit GMT, the system assumes
the values are the local time and date, converts them to Greenwich
mean time values, and sets the clock(s) with the Greenwich mean time.
Source
Timer supervision
Module
IEAVRTOD
Routing code
1
Descriptor code
2