IEA886A   TOD CLOCK(S) MUST BE SET

Explanation

The operator did not set the time-of-day (TOD) clock(s).

System action

The system prompts the operator for a reply. When you enter a valid reply to message IEA886A, the system issues message IEA903A.

Operator response

Use the following form of the REPLY command to set the time of day clock.
R id,‘DATE=[yyyy.ddd[,CLOCK=hh.mm.ss][,GMT]’
In the command text:
id
The reply identifier.
yyyy
The year (4 digit year: 1900 - 2042).
ddd
The day (001-366).
hh
The hour (00-23).
mm
The minute (00-59).
ss
The second (00-59).
Note: The apostrophes in the above reply are optional. If you include GMT in your reply, the system converts the time and date to Greenwich mean time. If you omit GMT, the system assumes the values are the local time and date, converts them to Greenwich mean time values, and sets the clock(s) with the Greenwich mean time.

Source

Timer supervision

Module

IEAVRTOD

Routing code

1

Descriptor code

2