IEA401I SDUMP NOT SCHEDULED FOR REMOTE DUMP. INCIDENT TOKEN:intoken REASON - reason
Explanation
The system was unable to write an SVC dump for another system in a sysplex.
In the message text:
- intoken
- The incident token for the dump. The token contains the name of the sysplex, the name of the system that originated the dump request, and the date and time of the request.
- reason
- One of the following:
- DUMP=NO WAS SET AT IPL OR INDICATED BY CHNGDUMP
- The installation indicated that no SVC dumps are to be written.
- NO SRBS COULD BE SCHEDULED TO START THE DUMP
- A system error occurred.
- SVC DUMP ABNORMALLY TERMINATED
- A system error occurred.
- A STATUS STOP SRBS CONDITION WAS DETECTED
- A system error occurred.
- NO STORAGE AVAILABLE
- The system could not acquire the storage needed to build the dump request; no dump was written.
- UNKNOWN
- A system error occurred.
System action
The system continues processing but does not write the requested SVC dump.
This message is sent to the console on which the DUMP command was entered or, if the dump was requested by another system in the sysplex but not by a DUMP command, to console ID 0.
System programmer response
Determine why the system could not write an SVC dump requested by another system in the sysplex. If the problem cannot be corrected, search problem reporting data bases for a fix for the problem. If no fix exists, contact the IBM® Support Center.
Source
SVC dump
Module
IEAVTSIT
Routing code
10
Descriptor code
4