IEA376I VIODSN PARAMETER IS 'IGNORE'. NO VIO JOURNALING
Explanation
The value of the VIODSN parameter in the IEASYSxx parmlib member used for this IPL is 'IGNORE' or null, which means that no VIO journaling will take place.
System action
IPL continues. The system rejects journaling requests for VIO data sets.
Operator response
If VIO journaling is necessary, re-IPL at direction of system programmer, specifying a VIO journaling data set name for the VIODSN parameter.
System programmer response
Ensure that VIO journaling is not required. If it is needed, specify VIODSN in IEASYSxx.
Source
Auxiliary Storage Manager (ASM)
Module
ILRASRM2
Routing code
Note 9
Descriptor code
4