IEA301I mem {NOT FOUND|IS ALIAS} IN dsname|PARMLIB
Explanation
The nucleus initialization program (NIP) detected an error condition.
- mem NOT FOUND IN dsname
- NIP could not find member mem of data set dsname.
- mem IS ALIAS IN dsname
- Member mem is an alias, but the directory of data set dsname also contains an alias entry for this member.
- dsname
- If the parmlib concatenation consists of only one data set, this is the name of that data set.
- PARMLIB
- If the parmlib concatenation consists of more than one data set, the member was not found in any of the parmlib data sets.
- IEA301I IEASYS00 NOT FOUND IN SYS1.PARMLIB
This message occurs even if the operator specified IEASYSxx parmlib members other than IEASYS00.
- IEA324I SYSP INPUT TERMINATED IN IEASYS00
- IEA336A RESPECIFY PARAMETERS OR PRESS ENTER TO CANCEL
System action
If the missing member is a required NIP module, the system enters a disabled wait state. If not, processing continues.
If message IEA301I is accompanied by messages IEA324I and IEA336A, the system resumes processing after the operator replies to message IEA336A.
Operator response
When message IEA301I is followed by IEA324I and IEA336A in the sequence shown above, reply to IEA336A by specifying the SYSP system parameter so that the system can access IEASYSxx parmlib members.
System programmer response
If the error occurred for the link list or LPA, determine what library the member is in. Determine if the library needs to be added to the concatenated list. Reinitialize the system.
If the error occurred in SYS1.PARMLIB, add the missing member to the data set.
If the member was in the data set, search problem reporting data bases for a fix for the problem. If no fix exists, contact the IBM® Support Center. Note that the IBM Support Center might request a stand-alone dump if the problem has recurred.
Source
System initialization (IPL/NIP)
Module
IEAVNIPM, IEAVNP13, IEAVNPC5, IEAVNPM4
Routing code
1
Descriptor code
12