IEA297W   LSQA IS EXHAUSTED IN A NON-MEMTERMABLE ADDRESS SPACE: ASID=xxxx JOBNAME=yyyyyyyy

Explanation

The system was unable to obtain storage from LSQA which was needed to process an SVC instruction. The system loaded a wait state because it was unable to terminate the address space of the program which issued the SVC.

In the message text:
xxxx
The address space ID, in hexadecimal, of the address space in which the problem occurred.
yyyyyyyy
The job name of the address space in which the problem occurred.

System action

The system enters a non-restartable wait state and issues message IEA297W.

Operator response

Provide a stand-alone dump if requested by the system programmer. ReIPL the system.

System programmer response

The problem might be caused by a loop which causes LSQA to be exhausted. If the source of the problem cannot be determined, search problem reporting data bases for a fix. If no fix exists, contact IBM® support center. Provide the stand-alone dump.

Source

Supervisor Control