IEA262I ETR PORT n IS NOT OPERATIONAL.
Explanation
The specified External Time Reference (ETR) port is not working. ETR is the MVS™ generic name for the IBM® Sysplex Timer (9037) or equivalent.
In
the message text:
- n
- The port number.
System action
The system continues processing. The system records the error in the logrec data set.
Operator response
One of the following:
- If an ETR is installed, check the system console associated with
this processor. If you have already contacted the IBM Support Center, no further action is required.
Otherwise, contact 9037 hardware support. Note that the same event might occur on more than one of the processors in a sysplex.
- If an ETR is not installed, ensure that the CLOCKxx member of SYS.PARMLIB contains ETRMODE NO and ETRZONE NO.
Source
Timer supervision
Module
IEATPORT
Routing code
10
Descriptor code
11