IEA231A SEVERE WTOR BUFFER SHORTAGE. 100% FULL
Explanation
The outstanding write to operator with reply (WTOR) messages have filled the buffer.
System action
The system puts tasks issuing WTOR macros in a wait state until the operator either reduces the number of outstanding WTORs or increases the number of WTOR buffers.
Operator response
Enter a DISPLAY R,R command to see the accumulated
WTOR messages. Do one of the following:
- Reply to outstanding WTOR messages.
- Cancel jobs that are currently issuing WTOR macros.
- Enter the CONTROL M,RLIM command to increase the number of WTOR
buffers. Note: The RLIM value cannot be higher than the RMAX value (RMAX is the highest possible reply ID). If you need to increase RLIM higher than RMAX, consider entering the CONTROL M,RMAX command to increase RMAX. To determine the current values of RLIM and RMAX, issue the K M,REF command.
The value of RMAX controls the number of digits in all reply IDs. For example, increasing RMAX to 100 (or higher) causes all WTORs to have 3-digit reply IDs. This might affect automation routines. Check with the system programmer before increasing RMAX higher than 99.
System programmer response
If the shortage recurs, increase the value for RLIM or RMAX in the CONSOLxx parmlib member.
Source
Communications task (COMMTASK)
Module
IEAVMQWR
Routing code
2,10
Descriptor code
2