IEA200I   memberxx - text

Explanation

During system initialization, the system could not use a data set member that was to contain an alternate version of the master scheduler JCL. In the message text:
memberxx
The member of SYS1.LINKLIB or SYS1.PARMLIB that the system could not use.
text
A description of the error, which is one of the following:
MEMBER NOT FOUND
The system could not find the MSTJCLxx parmlib member or MSTJCLxx load module in linklib that is to contain the alternate version of the master scheduler JCL.
I/O ERROR DURING BLDL
An input/output error occurred when the system used the build list to find the specified module.
I/O ERROR DURING READ
An input/output error occurred when the system was reading the data set that was to contain the alternate version of the master scheduler JCL.
UNEXPECTED END OF FILE
The system found an end-of-file (EOF) before the normal end of processing.
INTERNAL CONVERSION ERROR
An internal error occurred.
UNEXPECTED FAILURE
An internal error occurred.

System action

The system prompts the operator to respecify the MSTRJCL system parameter.

Operator response

Do the following:

  1. Contact the system programmer. Provide the message number and message text.
  2. At the request of the system programmer, do one of the following in response to the prompt to respecify the MSTRJCL system parameter:
    • Specify the MSTRJCL system parameter on the console; then press ENTER.
    • Press ENTER on the console.
  3. If the system prompts for the MSTRJCL system parameter again, ask the system programmer to correct the specified member.
  4. After the system programmer corrects the member, reIPL the system.

System programmer response

Validate that the MSTRJCL parameter in the IEASYSxx parmlib member specifies a MSTJCLxx parmlib member or MSTJCLxx CSECT in linklib that exists and is correct. If the member does not exist or is not correct, create or correct the member. Then ask the operator to enter the MSTRJCL system parameter again (in response to this message). Otherwise, ask the operator to enter the MSTRJCL parameter again (in response to this message).

Source

Master scheduler

Module

IEAVNP13

Routing code

Descriptor code