Example IECIOSxx parameters for hot I/O recovery

The following examples show how to specify the hot I/O recovery parameters in the IECIOSxx parmlib member. The values shown are also the IBM® default values.
HOTIO DVTHRSH=100    
  • Specifies 100 repeated interrupts as the threshold for the operating system recognizing the condition.
HOTIO DFLT110=(BOX,)    
  • For a non-DASD, non-dynamic pathing device. Box the device on the first occurrence of this condition. On recursion, prompt the operator.
HOTIO DFLT111=(CHPK,BOX)    
  • For a DASD or dynamic pathing device that is not reserved. Attempt channel path recovery for the device on first occurrence of this condition. On recursion, box the device.
HOTIO DFLT112=(CHPK,OPER)    
  • For a DASD or dynamic pathing device that is reserved. Attempt channel path recovery for the device on first occurrence of this condition. On recursion, prompt the operator.