Example IECIOSxx parameters for hot I/O recovery
The following examples show how to specify the hot I/O recovery
parameters in the IECIOSxx parmlib member. The values shown are also
the IBM® default values.
HOTIO DVTHRSH=100
- Specifies 100 repeated interrupts as the threshold for the operating system recognizing the condition.
HOTIO DFLT110=(BOX,)
- For a non-DASD, non-dynamic pathing device. Box the device on the first occurrence of this condition. On recursion, prompt the operator.
HOTIO DFLT111=(CHPK,BOX)
- For a DASD or dynamic pathing device that is not reserved. Attempt channel path recovery for the device on first occurrence of this condition. On recursion, box the device.
HOTIO DFLT112=(CHPK,OPER)
- For a DASD or dynamic pathing device that is reserved. Attempt channel path recovery for the device on first occurrence of this condition. On recursion, prompt the operator.