SETPRT—Execute form

A remote data management parameter list is referred to, and can be modified by, the execute form of the SETPRT macro.

The description of the standard form of the SETPRT macro explains the function of each parameter. The dcbaddr must be specified in the list or execute form of the SETPRT macro.

The execute form of the SETPRT macro is as follows:

dcbaddr—RX-Type Address or (2-12)
BURST={N|Y|*}
is coded as shown in the standard form of the macro, except for the * subparameter, which can be used only when INIT=Y is specified in the execute form of the SETPRT macro. When BURST=* is coded, the BURST field in the parameter list remains as previously set. This parameter is effective for the IBM® 3800 or 3900 printer only.
CHARS={name|A(address)|R(register)}
    {({name|A(address)|R( register)},...)}
    {*}
is coded as shown in the standard form of the macro, except for the * subparameter, which can be used only when INIT=Y is specified in the execute form of the SETPRT macro. When CHARS=* is coded, the CHARS field in the parameter list remains as previously set.
COPIES={number|*}
is coded as shown in the standard form of the macro, except for the * subparameter, which can be used only when INIT=Y is specified in the execute form of the SETPRT macro. When COPIES=* is coded, the COPIES field in the parameter list remains as previously set.
COPYNR={number|*}
is coded as shown in the standard form of the macro, except for the * subparameter, which can be used only when INIT=Y is specified in the execute form of the SETPRT macro. When COPYNR=* is coded, the COPYNR field in the parameter list remains as previously set.
COPYP={position|0}
is coded as shown in the standard form of the macro.
DISP={SCHEDULE|NOSCHEDULE|EXTERNAL}
is coded as shown in the standard form of the macro.
FCB={imageid|A(address)|R(register)}
    ({imageid|A(address)|R( register)}[,{V|A}[,N])
    {*}
is coded as shown in the standard form of the macro, except for the * subparameter, which can be used only when INIT=Y is specified in the execute form of the SETPRT macro. When FCB=* is coded, the FCB field in the parameter list remains as previously set.
FLASH={NONE|name}
    {NONE|([name],count)}
   {*}
is coded as shown in the standard form of the macro, except for the * subparameter, which can be used only when INIT=Y is specified in the execute form of the SETPRT macro. When FLASH=* is coded, the FLASH field in the parameter list remains as previously set.
INIT={N|Y}
is coded as shown in the standard form of the macro. When INIT=Y is specified on the execute form of the SETPRT macro, all 3800 or 3900 fields in the parameter list (BURST, CHARS, COPIES, COPYNR, FCB, FLASH, MODIFY, and REXMIT) are reset to binary zeros unless a specified field is preserved by coding keyword parameter=* or changed by specifying a valid subparameter for the keyword parameter as described in the standard form of the macro.
LIBDCB=dcb address—A-Type Address or (2-12)
is coded as shown in the standard form of the macro.
MODIFY={name|A(address)|R(register)}
    {({name|A(address)|R (register)},trc)}
    {*}
is coded as shown in the standard form of the macro, except for the * subparameter, which can be used only when INIT=Y is specified in the execute form of the SETPRT macro. When MODIFY=* is coded, the MODIFY field in the parameter list remains as previously set.
MSGAREA=address—A-Type Address or (2-12)
is coded as shown in the standard form of the macro.
OPTCD={B|U}
    {({B|U},{F|U})}
is coded as shown in the standard form of the macro.
PRTMSG={N|Y}
is coded as shown in the standard form of the macro.
PSPEED={L|M|H|N}
is coded as shown in the standard form of the macro.
REXMIT={N|Y|*}
is coded as shown in the standard form of the macro, except for the * subparameter, which can be used only when INIT=Y is specified in the execute form of the SETPRT macro. When REXMIT=* is coded, the REXMIT field in the parameter list remains as previously set.
UCS={csc}
{(csc,{F|F,V|V})}
is coded as shown in the standard form of the macro.
MF=(E,data management list address)
specifies that the execute form of the SETPRT macro is used, and that an existing data management parameter list is used.

E

data management list address—RX-Type Address, (2-12), or (1).