Logging off at a SNA RJP workstation LOGOFF

Function

The workstation operator can use the LOGOFF command to end an active session between the workstation logical unit (LU) and JES3. The LOGOFF command for unformatted system services users (such as the IBM® 3770 Data Communications System) is as follows:

Syntax

Read syntax diagramSkip visual syntax diagram
>>-LOGOFF--+------------------------+--------------------------->
           '-TYPE--+-(--COND--)---+-'   
                   '-(--UNCOND--)-'     

>--+---------------------+-------------------------------------><
   '-HOLD--+-(--YES--)-+-'   
           '-(--NO--)--'     

Parameters

TYPE (COND) or (UNCOND)
Specifies either conditional (COND) or unconditional (UNCOND) termination. For unconditional termination, JES3 checkpoints all active functions and disconnects the LU. For conditional termination, JES3 allows the currently active function to complete and then disconnects the LU.
HOLD (YES) or (NO)
YES specifies that the workstation-to-VTAM connection is retained. NO causes the workstation to disconnect from VTAM®.

The LOGOFF command for formatted system services users (such as the IBM 3790 Communications System) is workstation dependent and described in the appropriate document for that workstation.