Changing WTO pace-monitoring parameters *MODIFY,WTO

Function

Use the *MODIFY,WTO command to change the WTO pace-monitoring parameters for a specific processor in your JES3 installation. The original values were specified in the JESMSGLMT parameter on the MAINPROC statement in the JES3 initialization stream.

The results of the command are not checkpointed; you must reenter the command each time the affected processor is re-IPLed.

Syntax

Read syntax diagramSkip visual syntax diagram
>>-+-*MODIFY-+--,--WTO--+-,--main--------+---------------------->
   '-*F------'          |    .-,----.    |   
                        |    V      |    |   
                        '-(----main-+--)-'   

>--+-,--L--=--nnn--+---------------+-+-------------------------><
   |               '-,--I--=--nnnn-' |   
   '-,--I--=--nnnn--+--------------+-'   
                    '-,--L--=--nnn-'     

Parameters

main
Identifies the main where you want to modify the WTO pace-monitoring parameters.
L=nnn
Specifies the number (0–99999999) of messages allowed within the interval specified on the MAINPROC JESMSGLMT parameter or changed by the I=nnn parameter on this command.

If the number of messages issued by an address space exceeds the limit within the interval, JES3 issues message IAT6850 to indicate the job name and system.

I=nnn
Specifies the interval (0–32767 seconds) for the WTO pace monitoring.