Starting a SNA/NJE reader (NJERDR DSP) *CALL,NJERDR

Function

Use the *CALL,NJERDR command to start a NJE reader. The NJE reader prepares inbound job or SYSOUT streams for printing or further processing by JES3. You must start at least one NJE reader to receive SNA/NJE job and SYSOUT streams.

Syntax

Read syntax diagramSkip visual syntax diagram
>>-+-*CALL-+--,--NJERDR----------------------------------------><
   '-*X----'              

Rules

  • You can have as many as 255 NJE readers active at a time. JES3 assigns a job number to each active NJE reader.
  • JES3 issues the following message:
    *X NJERDR
     IAT6306  JOB (JOB33581) IS NJERDR , CALLED BY 01 IAT9225  NJERDR IS 
    ACTIVE