EZD0049I   ERROR error_code REGISTERING IP ADDR ipaddr AND PORT port FOR EE WORKLOAD QUEUEING ON INTERFACE interface_name

Explanation

An error occurred while the stack was registering an IP address and port for Enterprise Extender inbound workload queuing.

In the message text:
error_code
The OSA reject code returned from the OSA-Express microcode.
ipaddr
The static VIPA used for Enterprise Extender.
port
The UDP port used for Enterprise Extender.
interface_name
The name of the OSA-Express QDIO interface that supports inbound workload queueing.

System action

Enterprise Extender traffic that is received over this interface for this IP address and port is not eligible for inbound workload queuing. Instead, OSA-Express delivers this traffic to the stack by using the primary input queue.

Operator response

Contact the system programmer.

System programmer response

See OSA Error Codes in zEnterprise System and System z10 OSA-Express Customer's Guide and Reference for a description of the error code and potential action.

User response

Not applicable.

Problem determination

Not Applicable.

Source

z/OS® Communications Server TCP/IP

Module

EZBIFIND

Routing code

2, 8

Descriptor code

12

Automation

Not applicable.

Example

ERROR 0002 REGISTERING IP ADDR 200.1.1.1 AND PORT 12000 FOR EE WORKLOAD  QUEUEING ON INTERFACE OSAQDIO2