EZD0048I   INTERFACE interface_name DOES NOT SUPPORT QDIO INBOUND WORKLOAD QUEUEING

Explanation

The WORKLOADQ parameter was specified on the INTERFACE statement for this device in the TCP/IP profile. The OSA-Express adapter microcode level for this device does not support QDIO inbound workload queueing.

In the message text:
interface_name
The name of the interface.

System action

TCP/IP activates the device without QDIO inbound workload queueing enabled.

Operator response

Contact the system programmer.

System programmer response

Either install an OSA-Express Licensed Internal Code (LIC) level that supports QDIO inbound workload queueing or remove the WORKLOADQ parameter from the INTERFACE statement. QDIO inbound workload queueing is limited to OSA-Express3 ethernet features in QDIO mode (CHPID type OSD) that are running on an IBM® System z10™. Use the VTAM® DISPLAY TRL command to determine what OSA-Express LIC level is currently installed. See the information about the DISPLAY TRL command in z/OS Communications Server: SNA Operation for more information. See the 2097DEVICE Preventive Service Planning (PSP) bucket and the 2098DEVICE Preventive Service Planning (PSP) bucket for the OSA-Express LIC levels required for QDIO inbound workload queueing support.

See the information about the QDIO inbound workload queueing in z/OS Communications Server: IP Configuration Guide for information about the networking affects of configuring with and without the WORKLOADQ parameter.

User response

Not applicable.

Problem determination

Not applicable.

Source

z/OS® Communications Server TCP/IP

Module

EZBIFIND

Routing code

2,8

Descriptor code

12

Automation

None.

Example

EZD0048I INTERFACE OSAQDIO4 DOES NOT SUPPORT QDIO INBOUND WORKLOAD QUEUEING